Table 2 of Benitez-del-Castillo, Mol Vis 2021; 27:243-261.


Table 2. Tear sample volume required (per patient) for quantification with standard ELISA and multiplex antibody microarrays.

Biomarker ELISA Microarrays
Dilution Final volume per well (µl) Vol. sample needed* (µl) Dilution Final volume per well (µl) Vol. sample needed** (µl)
CST4 1:100 100 2 1:70 70 1
MMP9 3:100 100 6    
S100A6 2:100 100 4    
S100A8 2:100 100 4 N/A N/A N/A
  Total volume (µl) 16 Total volume (µl) 1