Table 1.
Positive cell counts per mm2 assessed by immunostaining. The asterisk indicates a p<0.001 compared to BSS-injected conjunctivas, the sharp (hash mark) denotes a p<0.005 compared to LPS+anti-TNF-α-injected conjunctivas, and the double asterisk indicates a p<0.01 compared to BSS-injected conjunctivas.
Assay BSS LPS LPS+anti-TNF-α ------ ------- ---------- -------------- TNF-α 133±115 3989±360*# 833± 57** TNFR-1 126±100 2978±458*# 867± 57** CD4 233±103 2985±211*# 899±112** CD8 200± 65 1033±152*# 578±178** TUNEL 0 166± 57*# 0 |